Tree Allometrics

Equations / Aboveground biomass

Mixed mangrove total aboveground biomass, power model (D^2 H)

Aboveground biomassSeven mangrove species (Bruguiera cylindrica, B. parviflora, B. sexangula, Ceriops tagal, Rhizophora apiculata, R. mucronata, Xylocarpus granatum)MalaysianaturalRead from the original paper

Fitted on these 7 species: Bruguiera cylindrica, Bruguiera parviflora, Bruguiera sexangula, Ceriops tagal, Rhizophora apiculata, Rhizophora mucronata, Xylocarpus granatum

4 of the 7 species it was fitted on · iNaturalist photos, hover for credit
Equation

As printed (Table 2)

Total biomass 0.0739D2H0.9291 0.9556

In this library's units, ready to compute (kg)

Aboveground biomass = 0.0739 * (D^2 * H)^0.9291
D
Diameter at breast height (1.3 m), cm
H
Total tree height, m

Equation form a(D^2 H)^b read from Table 2 (printed 'D2H' with exponent; the paper's equation images were not in the text copy read). Output in kg dry mass. D was measured at about 1.37 m above ground, above the highest stilt root for Rhizophora (Section 2.2). H in the paper is "stem height" (Table 2 note; Section 2.3), not total tree height; it is mapped to canonical H here. The paper's best model, Eq. 3 with wood density (0.00475 ρ^0.6309 D^2.28787, R2 0.9697), is not added.

Source
Destructive sampling was conducted using the selective random sampling method on 15 standing trees.
Trees measured · Abstract
in the range of DBH from 9.0 cm to 33.0 cm
Smallest DBH · Section 3.1
0.9556
R² · Table 2
Trees measured
15
DBH range
9–33 cm
R²
0.9556
Method
power function (intrinsically linear), SPSS general linear model
Where
Sungai Pulai Forest Reserve, Johor
Last checked
2026-11-02
Calculate
Height from
53.6
Aboveground biomass (kg)
25.2
Carbon (kg), ×0.47
92.4
CO₂e (kg), ×44/12
Fitted DBH range0100200300400500600700800510152025303540DBH (cm)Aboveground biomass (kg)Aboveground biomass

Shaded: the DBH range the model was fitted on. Other inputs held at the values above.

Checks this equation passes

On every build, the library's form and the paper's own form (in its units) must both give these values within 1%.

InputsExpectedWe getFrom
D = 10, H = 1253.653.6Computed from the printed form
computed from the published form (coefficients as printed)
D = 20, H = 19.5305305Computed from the printed form
computed from the published form (coefficients as printed)
D = 30, H = 22726726Computed from the printed form
computed from the published form (coefficients as printed)

Report a problem with this equation · JSON

Related

Compare these curves